• Documents
  • Authors
  • Tables
  • Log in
  • Sign up
  • MetaCart
  • DMCA
  • Donate

CiteSeerX logo

Advanced Search Include Citations

Tools

Sorted by:
Try your query at:
Semantic Scholar Scholar Academic
Google Bing DBLP
Results 1 - 10 of 6,462
Next 10 →

structural distortions

by Gernot Kostorz, Branton J. Campbell, Harold T. Stokes, David E. Tanner, Dorian M. Hatch, Branton J. Campbell, Harold T. Stokes, David E. Tanner, Dorian M. Hatch , 2006
"... Copyright © International Union of Crystallography Author(s) of this paper may load this reprint on their own web site provided that this cover page is retained. Republication of this article or its storage in electronic databases or the like is not permitted without prior permission in writing from ..."
Abstract - Add to MetaCart
Copyright © International Union of Crystallography Author(s) of this paper may load this reprint on their own web site provided that this cover page is retained. Republication of this article or its storage in electronic databases or the like is not permitted without prior permission in writing from the IUCr. J. Appl. Cryst. (2006). 39, 607–614 Branton J. Campbell et al. ISODISPLACE computer programs

Structural distortion in Ludwigites

by unknown authors
"... Structural distortion in a three-leg-ladder is studied in connection with Ludwigites, in particular the Fe and Co homometallic ones. Static impurities in t2g-orbitals as infinite repulsion potentials randomly located in the three-leg-ladder and a Su-Schrieffer-Heeger like tight-binding Hamiltonian a ..."
Abstract - Add to MetaCart
Structural distortion in a three-leg-ladder is studied in connection with Ludwigites, in particular the Fe and Co homometallic ones. Static impurities in t2g-orbitals as infinite repulsion potentials randomly located in the three-leg-ladder and a Su-Schrieffer-Heeger like tight-binding Hamiltonian

Video Quality Assessment Based on Structural Distortion Measurement

by Zhou Wang, Ligang Lu, Alan C. Bovik , 2004
"... Objective image and video quality measures play important roles in a variety of image and video processing applications, such as compression, communication, printing, analysis, registration, restoration, enhancement and watermarking. Most proposed quality assessment approaches in the literature are ..."
Abstract - Cited by 166 (23 self) - Add to MetaCart
are error sensitivity-based methods. In this paper, we follow a new philosophy in designing image and video quality metrics, which uses structural distortion as an estimate of perceived visual distortion. A computationally e#cient approach is developed for full-reference (FR) video quality assessment

Distortion invariant object recognition in the dynamic link architecture

by Martin Lades, Jan C. Vorbrüggen, Joachim Buhmann, Christoph v. d. Malsburg, Rolf P. Würtz, Wolfgang Konen - IEEE TRANSACTIONS ON COMPUTERS , 1993
"... We present an object recognition system based on the Dynamic Link Architecture, which is an extension to classical Artificial Neural Networks. The Dynamic Link Architecture ex-ploits correlations in the fine-scale temporal structure of cellular signals in order to group neurons dynamically into hig ..."
Abstract - Cited by 637 (80 self) - Add to MetaCart
We present an object recognition system based on the Dynamic Link Architecture, which is an extension to classical Artificial Neural Networks. The Dynamic Link Architecture ex-ploits correlations in the fine-scale temporal structure of cellular signals in order to group neurons dynamically

Image Quality Assessment: From Error Visibility to Structural Similarity

by Zhou Wang, Alan C. Bovik, Hamid R. Sheikh, Eero P. Simoncelli - IEEE TRANSACTIONS ON IMAGE PROCESSING , 2004
"... Objective methods for assessing perceptual image quality have traditionally attempted to quantify the visibility of errors between a distorted image and a reference image using a variety of known properties of the human visual system. Under the assumption that human visual perception is highly adapt ..."
Abstract - Cited by 1499 (114 self) - Add to MetaCart
Objective methods for assessing perceptual image quality have traditionally attempted to quantify the visibility of errors between a distorted image and a reference image using a variety of known properties of the human visual system. Under the assumption that human visual perception is highly

The Effect of Structural Distortions on the Electronic Structure of Carbon Nanotubes

by Alain Rochefort, Dennis R. Salahub, Phaedon Avouris - Chemical Physics Letters , 1998
"... We calculated the effects of structural distortions on the electronic structure of carbon nanotubes. The main effect of nanotube bending is an increased mixing of σ and π-states. This mixing leads to an enhanced density-of-states in the valence band near the Fermi energy. While in a straight tube th ..."
Abstract - Cited by 7 (0 self) - Add to MetaCart
We calculated the effects of structural distortions on the electronic structure of carbon nanotubes. The main effect of nanotube bending is an increased mixing of σ and π-states. This mixing leads to an enhanced density-of-states in the valence band near the Fermi energy. While in a straight tube

Statistics for Experimenters

by Gerald O. Hunter, Matthias Zeller, Brian D. Leskiw, Bruker Smart, Apex Ccd , 2005
"... R factor = 0.052; wR factor = 0.114; data-to-parameter ratio = 18.4. The title compound, [Zn(C8H10F3O2)2(CH4O)2], is a dimethanol coordinated zinc complex with the acetyl acetonate derivative 1,1,1-trifluoro-5,5-dimethylhexane-2,4dionate. The bis--diketonate complex, which is isostructural with its ..."
Abstract - Cited by 675 (1 self) - Add to MetaCart
Co analogue, is located on a crystallographic inversion center. The complex is octahedral with basically no distortion, and the methanol molecules are in trans positions with respect to one another. The planes of the-diketonate and the ZnO4 unit are tilted by 18.64 (10) against each other. O—H O

Video Quality Assessment Using Structural Distortion Measurement

by Zhou Wang Ligang, Zhou Wang, Ligang Lu, Alan C. Bovik - in Proc. IEEE Int. Conf. Image Proc , 2002
"... Objective image/video quality measures play important roles in various image/video processing applications, such as compression, communication, printing, analysis, registration, restoration and enhancement. Most proposed quality assessment approaches in the literature are error sensitivity-based met ..."
Abstract - Add to MetaCart
-based methods. In this paper, we follow a new philosophy in designing image/video quality metrics, which uses structural distortion as an estimation of perceived visual distortion. We develop a new approach for video quality assessment. Experiments on the video quality experts group (VQEG) test data set shows

Motion bias and structure distortion induced by calibration errors

by Marco Zucchelli , 2001
"... This article provides an account of sensitivity and robustness of structure and motion recovery with respect to the errors in intrinsic parameters of the camera. We demonstrate both analytically and in simulation, the interplay between measurement and calibration errors and their effect on motion an ..."
Abstract - Cited by 2 (0 self) - Add to MetaCart
and structure estimates. In particular we show that the calibration errors introduce an additional bias towards the optical axis, which has opposite sign to the bias typically observed by egomotion algorithms. The overall bias causes a distortion of the resulting 3D structure, which we express in a parametric

Local Structural Distortions in Quenched Au-Cu Alloys

by A. I. Frenkel, E. A. Stem, A. Rubshtein, A. Voronel, Yu. Rosenberg
"... Abstract: Disordered alloys Au,Cul-, prepared by melt spinning method were analyzed by XAFS taken at 80 K. Local atomic structure around Au and Cu atoms was measured and strong deviations from perfect fcc structure were obtained resulting from the size disparity between Au and Cu atoms. A sharp asym ..."
Abstract - Add to MetaCart
Abstract: Disordered alloys Au,Cul-, prepared by melt spinning method were analyzed by XAFS taken at 80 K. Local atomic structure around Au and Cu atoms was measured and strong deviations from perfect fcc structure were obtained resulting from the size disparity between Au and Cu atoms. A sharp
Next 10 →
Results 1 - 10 of 6,462
Powered by: Apache Solr
  • About CiteSeerX
  • Submit and Index Documents
  • Privacy Policy
  • Help
  • Data
  • Source
  • Contact Us

Developed at and hosted by The College of Information Sciences and Technology

© 2007-2019 The Pennsylvania State University