• Documents
  • Authors
  • Tables
  • Log in
  • Sign up
  • MetaCart
  • DMCA
  • Donate

CiteSeerX logo

Advanced Search Include Citations

Tools

Sorted by:
Try your query at:
Semantic Scholar Scholar Academic
Google Bing DBLP
Results 1 - 10 of 1,572
Next 10 →

Research Article RET Screen Assessment of Utility Scale Wind Power Generation Based on Historical Wind Speed Data-the Case of Mankoadze in the Central Region of Ghana

by Emmanuel Yeboah Osei , Emmanuel Yeboah Osei , Eric Osei Essandoh , 2014
"... Abstract: With cost being a vital factor for determining how feasible any power project will be, this study demonstrates that a 50 MW grid-connected wind power plant at Mankoadze in the Central Region of Ghana will be technically and financially viable and competitive at a certain minimum feed-in-t ..."
Abstract - Add to MetaCart
Abstract: With cost being a vital factor for determining how feasible any power project will be, this study demonstrates that a 50 MW grid-connected wind power plant at Mankoadze in the Central Region of Ghana will be technically and financially viable and competitive at a certain minimum feed

By Princeton Energy Resources International, LLC.

by Dan Ancona, Jim Mcveigh , 2001
"... Recognition of the value of wind energy as a low cost, clean source for electricity is creating major new business opportunities for manufacturing and materials innovation. Worldwide growth in wind generation since 1994 has been 30 % or higher annually. The cost of energy from large wind power plant ..."
Abstract - Add to MetaCart
plants and small turbines for distributed generation is now $4-5 billion annually worldwide and growing. Small turbines (less than 100 kW each) are being produced for the growing distributed generation and off-grid markets. Grid-connected wind power plants typically employ hundreds of 1 to 2 MW turbines

Short-term Forecast of Power Generation for Grid-Connected

by Ying-zi Li, Jin-cang Niu, Li Li - Photovoltaic System Based on Advanced Grey-Markov Chain. Iceet: 2009 International Conference on Energy and Environment Technology
"... Being photovoltaic power generation affected by radiation strength, wind speed, clouds cover and environment tem-perature, the generating in each moment is fluctuating. The operational characteristics of grid-connected PV systems are coincided with gray theory application conditions. A gray theory m ..."
Abstract - Cited by 3 (0 self) - Add to MetaCart
Being photovoltaic power generation affected by radiation strength, wind speed, clouds cover and environment tem-perature, the generating in each moment is fluctuating. The operational characteristics of grid-connected PV systems are coincided with gray theory application conditions. A gray theory

(Simulation of Reactive Power Compensation in Grid-Connected Wind Power Generation System)

by Kyoung-soo Ro․bo-kyoung Jang
"... Reactive power support is considered to be necessary for dealing with a voltage stability issue with wind turbine system employing squirrel-cage induction generator(SCIG). This paper analyses steady-state characteristics of the SCIG wind turbine system by simulating torque-slip characteristics of SC ..."
Abstract - Add to MetaCart
Reactive power support is considered to be necessary for dealing with a voltage stability issue with wind turbine system employing squirrel-cage induction generator(SCIG). This paper analyses steady-state characteristics of the SCIG wind turbine system by simulating torque-slip characteristics

Multilevel Power Conditioner for Grid-Connected Photovoltaic Applications

by G. Gr, D. Ostojic, C. Rossi, D. Casadei, Senior Member, Gabriele Gr, Darko Ostojic, Claudio Rossi, Domenico Casadei Are
"... Abstract–-A novel scheme for three-phase grid-connected photovoltaic (PV) generation systems is presented in this paper. The proposed scheme is based on two insulated strings of PV panels, each one feeding a standard two-level three-phase voltage source inverter (VSI). Inverters are connected to gri ..."
Abstract - Add to MetaCart
Abstract–-A novel scheme for three-phase grid-connected photovoltaic (PV) generation systems is presented in this paper. The proposed scheme is based on two insulated strings of PV panels, each one feeding a standard two-level three-phase voltage source inverter (VSI). Inverters are connected

Initialisation of Grid-Connected Wind Turbine Models in Power-System Simulations

by unknown authors
"... This paper describes a method of initialising dynamic wind turbine models in power-system simulations. The method uses grid-status information to initialise the grid-connected wind turbine model. The goal is to start a power-system simulation in a stationary state, without unnecessary transient beha ..."
Abstract - Add to MetaCart
This paper describes a method of initialising dynamic wind turbine models in power-system simulations. The method uses grid-status information to initialise the grid-connected wind turbine model. The goal is to start a power-system simulation in a stationary state, without unnecessary transient

Estimation of reliability evaluation of Wind Power plant connected to power grid: An Analysis

by Ravi Shankar Garg , Anurag Gour , Dr Mukesh Pandey
"... Abstract : The grid was also able to keep up voltage and frequency, and was able to provide any reactive power that was needed. India of 58 numbers of 225 KW each (13.5 MW).The reliability evaluation result of 10 units of Dewas plant connected to eastern grid were predictable. The estimates were ba ..."
Abstract - Add to MetaCart
Abstract : The grid was also able to keep up voltage and frequency, and was able to provide any reactive power that was needed. India of 58 numbers of 225 KW each (13.5 MW).The reliability evaluation result of 10 units of Dewas plant connected to eastern grid were predictable. The estimates were

Control Methods for Low Voltage Ride-Through Compliance in Grid-Connected NPC Converter Based Wind Power Systems Using Predictive Control

by Depto Electrónica
"... Abstract-- In presence of grid voltage dips, Low Voltage Ride-Through (LVRT) requirements demand the wind power plant to remain connected to the grid, helping the network to keep voltage and frequency stable. Neutral-Point-Clamped (NPC) converters are appropriate for wind power systems, because the ..."
Abstract - Add to MetaCart
Abstract-- In presence of grid voltage dips, Low Voltage Ride-Through (LVRT) requirements demand the wind power plant to remain connected to the grid, helping the network to keep voltage and frequency stable. Neutral-Point-Clamped (NPC) converters are appropriate for wind power systems, because

Grid-Connected Photovoltaic-Fuel Cell Hybrid Power Plant

by Kyoungsoo Ro University, Robert P. Broadwater, Yilu Liu, John W. Roach, Grid-connected Photovoltaic-fuel, Grid-connected Photovoltaic-fuel, Cell Hybrid, Cell Hybrid, Power Plant, Power Plant, Kyoungsoo Ro, Kyoungsoo Ro
"... The study started with the requirement that a photovoltaic (PV) power source should be integrated with other supplementary power sources whether it operates in a stand-alone or gridconnected mode. First, fuel cells for a backup of varying PV power were compared in detail with batteries and were foun ..."
Abstract - Add to MetaCart
found to have more operational benefits. Next, maximizing performance of a grid-connected PV-fuel cell hybrid system by use of a two-loop controller was discussed. One loop is a neural network controller for maximum power point tracking, which extracts maximum available solar power from PV arrays under

Modeling and Experimental Study on Grid-Connected Inverter for Direct Drive Wind Turbine

by Huang Wang-jun, Zeng Zhi-gang, Zhou Hui-fang, Ten Yuan-jiang, Li Li , 2013
"... This paper designs a dual topological structure of grid-connected inverter for high-power wind turbine, introduces PWM converter's operational state, and establishes its mathematical model, then it puts forward the dual closed-loop vector control strategy of grid-side converter based on dq coor ..."
Abstract - Cited by 2 (0 self) - Add to MetaCart
This paper designs a dual topological structure of grid-connected inverter for high-power wind turbine, introduces PWM converter's operational state, and establishes its mathematical model, then it puts forward the dual closed-loop vector control strategy of grid-side converter based on dq
Next 10 →
Results 1 - 10 of 1,572
Powered by: Apache Solr
  • About CiteSeerX
  • Submit and Index Documents
  • Privacy Policy
  • Help
  • Data
  • Source
  • Contact Us

Developed at and hosted by The College of Information Sciences and Technology

© 2007-2019 The Pennsylvania State University