ORIGINAL ARTICLE The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
"... Introduction: The purpose of the study was to evaluate the performance and usability of the FreeStyle Libre Flash glucose monitoring system (Abbott Diabetes Care, Alameda, CA) for interstitial glucose results compared with capillary blood glucose results. Materials and Methods: Seventy-two study pa ..."
Abstract
- Add to MetaCart
Introduction: The purpose of the study was to evaluate the performance and usability of the FreeStyle Libre Flash glucose monitoring system (Abbott Diabetes Care, Alameda, CA) for interstitial glucose results compared with capillary blood glucose results. Materials and Methods: Seventy-two study
Prevention of nocturnal hypoglycemia using predictive alarm algorithms and insulin pump suspension, Diabetes Care 33 (5
, 2010
"... OBJECTIVE — The aim of this study was to develop a partial closed-loop system to safely prevent nocturnal hypoglycemia by suspending insulin delivery when hypoglycemia is predicted in type 1 diabetes. RESEARCH DESIGN AND METHODS — Forty subjects with type 1 diabetes (age range 12–39 years) were stud ..."
Abstract
-
Cited by 3 (0 self)
- Add to MetaCart
of five (n � 16) algorithms predicted hypoglycemia based on the glucose levels measured with the FreeStyle Navigator (Abbott Diabetes Care). RESULTS — The standardized protocol induced hypoglycemia on 13 (93%) of the 14 nights. With use of a voting scheme that required three algorithms to trigger insulin
regimens: Results of a Pilot Trial Diabetes Research in Children Network (DirecNet) Study Group Running Title: FreeStyle Navigator™ Corresponding Author:
, 2007
"... In a previous pilot study of the FreeStyle Navigator ™ Continuous Glucose Monitoring System (“Navigator”, Abbott Diabetes Care) in 30 children and adolescents with type 1 diabetes (T1D) using insulin pumps, we found that Navigator use averaged>130 hours per week over 13 weeks and mean HbA1c dropp ..."
Abstract
- Add to MetaCart
In a previous pilot study of the FreeStyle Navigator ™ Continuous Glucose Monitoring System (“Navigator”, Abbott Diabetes Care) in 30 children and adolescents with type 1 diabetes (T1D) using insulin pumps, we found that Navigator use averaged>130 hours per week over 13 weeks and mean HbA1c
Running title: Meal Detection Algorithm For Artificial β-cell Corresponding author:
, 2007
"... Objective: The purpose of this study was to introduce a novel meal detection algorithm (MDA) to be used as part of an artificial β-cell that utilizes continuous glucose monitoring (CGM). Research Design And Methods: We developed our MDA on a data set of 26 meal events using records from nineteen chi ..."
Abstract
- Add to MetaCart
children 1 to 6 year old who used the Medtronic Minimed CGMS Gold®. We then applied this algorithm to CGM records from a DirecNet pilot study of the FreeStyle Navigator ® (Abbott Diabetes Care). During a research center admission, breakfast insulin was withheld for 1 hour and discrete glucose levels were
Motivational predictors of weight loss and weight-loss maintenance
- Journal of Personality and Social Psychology
, 1996
"... Self-determination theory proposes that behavior change will occur and persist if it is autonomously motivated. Autonomous motivation for a behavior is theorized to be a function both of individual differences in the autonomy orientation from the General Causality Orientations Scale and of the degre ..."
Abstract
-
Cited by 147 (22 self)
- Add to MetaCart
climate created by the health-care staff. Recent statistics indicate that more than 12 million Ameri-can adults are severely obese and face significant health risks due to their weight (Kissebah, Freedman, & Peiris, 1989; Kuczmarski, 1992). ~ In addition to being linked to heart dis
Diabetes Treatment Satisfaction Questionnaire: Change version for use alongside status version provides appropriate solution where ceiling effects occur. Diabetes Care
, 1999
"... (DTSQc) evaluated in insulin glargine trials shows greater responsiveness to improvements than the original DTSQ ..."
Abstract
-
Cited by 89 (3 self)
- Add to MetaCart
(DTSQc) evaluated in insulin glargine trials shows greater responsiveness to improvements than the original DTSQ
Simpson K: Comorbid Depression is Associated With Increased Health Care Use and Expenditures
- in Individuals With Diabetes. Diabetes Care 2002
"... OBJECTIVE — This study ascertained the odds of diagnosed depression in individuals with diabetes and the relation between depression and health care use and expenditures. RESEARCH DESIGN AND METHODS — First, we compared data from 825 adults with diabetes with that from 20,688 adults without diabetes ..."
Abstract
-
Cited by 88 (1 self)
- Add to MetaCart
OBJECTIVE — This study ascertained the odds of diagnosed depression in individuals with diabetes and the relation between depression and health care use and expenditures. RESEARCH DESIGN AND METHODS — First, we compared data from 825 adults with diabetes with that from 20,688 adults without
ORIGINAL ARTICLE Accuracy of Continuous Glucose Monitoring During Three Closed-Loop Home Studies Under Free-Living Conditions
"... Objectives: Closed-loop (CL) systems modulate insulin delivery based on glucose levels measured by a con-tinuous glucose monitor (CGM). Accuracy of the CGM affects CL performance and safety. We evaluated the accuracy of the Freestyle Navigator II CGM (Abbott Diabetes Care, Alameda, CA) during three ..."
Abstract
- Add to MetaCart
Objectives: Closed-loop (CL) systems modulate insulin delivery based on glucose levels measured by a con-tinuous glucose monitor (CGM). Accuracy of the CGM affects CL performance and safety. We evaluated the accuracy of the Freestyle Navigator II CGM (Abbott Diabetes Care, Alameda, CA) during