Results 1 - 10
of
36,218
Image registration methods: a survey
- IMAGE AND VISION COMPUTING
, 2003
"... This paper aims to present a review of recent as well as classic image registration methods. Image registration is the process of overlaying images (two or more) of the same scene taken at different times, from different viewpoints, and/or by different sensors. The registration geometrically align t ..."
Abstract
-
Cited by 734 (9 self)
- Add to MetaCart
This paper aims to present a review of recent as well as classic image registration methods. Image registration is the process of overlaying images (two or more) of the same scene taken at different times, from different viewpoints, and/or by different sensors. The registration geometrically align
FAST VOLUME RENDERING USING A SHEAR-WARP FACTORIZATION OF THE VIEWING TRANSFORMATION
, 1995
"... Volume rendering is a technique for visualizing 3D arrays of sampled data. It has applications in areas such as medical imaging and scientific visualization, but its use has been limited by its high computational expense. Early implementations of volume rendering used brute-force techniques that req ..."
Abstract
-
Cited by 541 (2 self)
- Add to MetaCart
Volume rendering is a technique for visualizing 3D arrays of sampled data. It has applications in areas such as medical imaging and scientific visualization, but its use has been limited by its high computational expense. Early implementations of volume rendering used brute-force techniques
Estimating the Support of a High-Dimensional Distribution
, 1999
"... Suppose you are given some dataset drawn from an underlying probability distribution P and you want to estimate a "simple" subset S of input space such that the probability that a test point drawn from P lies outside of S is bounded by some a priori specified between 0 and 1. We propo ..."
Abstract
-
Cited by 766 (29 self)
- Add to MetaCart
Suppose you are given some dataset drawn from an underlying probability distribution P and you want to estimate a "simple" subset S of input space such that the probability that a test point drawn from P lies outside of S is bounded by some a priori specified between 0 and 1. We
Database resources of the National Center for Biotechnology Information
- Nucleic Acids Res
, 2008
"... In addition to maintaining the GenBankÒ nucleic acid sequence database, the National Center for Biotechnology Information (NCBI) provides analysis and retrieval resources for the data in GenBank and other biological data made available through NCBI’s Web site. NCBI resources include Entrez, ..."
Abstract
-
Cited by 964 (15 self)
- Add to MetaCart
In addition to maintaining the GenBankÒ nucleic acid sequence database, the National Center for Biotechnology Information (NCBI) provides analysis and retrieval resources for the data in GenBank and other biological data made available through NCBI’s Web site. NCBI resources include Entrez,
Testing and Diagnosis of Realistic Defects in Digital Microfluidic Biochips
, 2007
"... Microfluidics-based biochips are soon expected to revolutionize biosensing, clinical diagnostics and drug discovery. Robust off-line and on-line test techniques are required to ensure system dependability as these biochips are deployed for safety-critical applications. Due to the underlying mixed-t ..."
Abstract
-
Cited by 11 (10 self)
- Add to MetaCart
Microfluidics-based biochips are soon expected to revolutionize biosensing, clinical diagnostics and drug discovery. Robust off-line and on-line test techniques are required to ensure system dependability as these biochips are deployed for safety-critical applications. Due to the underlying mixed
Reconfiguration Techniques for Digital Microfluidic Biochips*
"... As digital microfluidic biochips become widespread in safety-critical biochemical applications, system dependability emerges as a critical performance parameter. The dynamic reconfigurability inherent in digital microfluidic biochips can be utilized to bypass faulty cells, thereby supporting defect/ ..."
Abstract
- Add to MetaCart
As digital microfluidic biochips become widespread in safety-critical biochemical applications, system dependability emerges as a critical performance parameter. The dynamic reconfigurability inherent in digital microfluidic biochips can be utilized to bypass faulty cells, thereby supporting defect
Functional testing of digital microfluidic biochips
- Proc. ITC
, 2007
"... Dependability is an important attribute for microfluidic biochips that are used for safety-critical applications such as point-of-care health assessment, air-quality monitoring, and food-safety testing. Therefore, these devices must be adequately tested after manufacture and during bioassay operatio ..."
Abstract
-
Cited by 16 (9 self)
- Add to MetaCart
Dependability is an important attribute for microfluidic biochips that are used for safety-critical applications such as point-of-care health assessment, air-quality monitoring, and food-safety testing. Therefore, these devices must be adequately tested after manufacture and during bioassay
Parallel Scan-Like Test and Multiple-Defect Diagnosis for Digital Microfluidic Biochips
, 2007
"... Dependability is an important attribute for microfluidic biochips that are used for safety-critical applications such as point-of-care health assessment, air-quality monitoring, and food-safety testing. Therefore, these devices must be adequately tested after manufacture and during bioassay operati ..."
Abstract
-
Cited by 20 (12 self)
- Add to MetaCart
operations. We propose a parallel scan-like testing methodology for digital microfluidic devices. A diagnosis method based on test outcomes is also proposed. The diagnosis technique is enhanced such that multiple defect sites can be efficiently located using parallel scan-like testing. Defect diagnosis can
Results 1 - 10
of