Results 1 - 10
of
3,010
Quartz crystal microbalance Circular amplification ATP
, 2013
"... A sensitive quartz crystal microbalance assay of adenosine triphosphate via DNAzyme-activated and aptamer-based target-triggering circular amplification ..."
Abstract
- Add to MetaCart
A sensitive quartz crystal microbalance assay of adenosine triphosphate via DNAzyme-activated and aptamer-based target-triggering circular amplification
Detection of Fibrinogen and Coagulation Factor VIII in Plasma by a Quartz Crystal Microbalance Biosensor
, 2013
"... sensors ..."
RHEOMETRY FOR BLOOD COAGULATION STUDIES
"... This review considers some of the various rheometrical approaches that have been adopted to study blood coagulation, with special reference to the rheological assessment of clotting time and studies of the evolution of viscoelasticity during the course of fibrin polymerization and cross-linking. A c ..."
Abstract
-
Cited by 1 (0 self)
- Add to MetaCart
rheometry, various forms of wave propagation measurements and other, less widely used techniques such as free oscillation rheometry, quartz crystal microbalance measurements and surface plasmon resonance.
Open Access Investigation of Interaction of Vaccinia Virus Complement Control Protein and Curcumin with Complement Components C3 and C3b Using Quartz Crystal Microbalance with Dissipation Monitoring Technology
"... Abstract: C3 and C3b, the components central to the complement activation, also play a damaging role in several inflammatory disorders. Vaccinia virus complement control protein (VCP) and curcumin (Cur) are natural compounds with different biological origins reported to regulate complement activatio ..."
Abstract
- Add to MetaCart
microbalance with dissipation monitoring (QCM-D) is a novel technology used to study the interaction of biomolecules. This technology was applied to characterize the interactions of VCP, Cur and appropriate controls with the key complement components. Cur as well as VCP showed binding to both C3 and to C3b
SUPPORTED ON MICROBALL BEARINGS
, 2007
"... The design, fabrication, and characterization of a rotary micromotor supported on microball bearings are reported in this dissertation. This is the first demonstration of a rotary micromachine with a robust mechanical support provided by microball-bearing technology. One key challenge in the realiza ..."
Abstract
- Add to MetaCart
element method. The geometry of the micromotor is optimized based on the simulation results. The development of the rotary machine is based on studies of fabrication and testing of linear micromotors. The stator and rotor are fabricated separately on silicon substrates and assembled with the stainless
Article Biomimetic Receptors for Bioanalyte Detection by Quartz Crystal Microbalances — From Molecules to Cells †
, 2014
"... sensors ..."
1 STUDY AND CHARACTERIZATION OF ELECTROACTIVE MATERIALS BY COUPLING OF ELECTROCHEMICAL AND ACOUSTIC TECHNIQUES
"... Electrochemical quartz crystal microbalance (EQCM)...................................12 ..."
Abstract
- Add to MetaCart
Electrochemical quartz crystal microbalance (EQCM)...................................12
Article Comparison of a Resonant Mirror Biosensor (IAsys) and a Quartz Crystal Microbalance (QCM) for the Study on Interaction between Paeoniae Radix 801 and Endothelin-1
, 2008
"... sensors ..."
The quartz crystal microbalance as a continuous monitoring tood for the study of endothelial cell surface attachment and growth. Biotechnol. Prog. 16:268-277. 76 77 A
- Bushway University of Maine, Department of
"... The quartz crystal microbalance (QCM) was used to monitor endothelial cell (EC) adhesion on the gold surface of an oscillating quartz crystal contained in a QCM device. A number of parameters were investigated. First, we observed differential QCM O-ring toxicities for ECs. Second, appropriate condit ..."
Abstract
-
Cited by 2 (0 self)
- Add to MetaCart
The quartz crystal microbalance (QCM) was used to monitor endothelial cell (EC) adhesion on the gold surface of an oscillating quartz crystal contained in a QCM device. A number of parameters were investigated. First, we observed differential QCM O-ring toxicities for ECs. Second, appropriate
Results 1 - 10
of
3,010