P" C. Richards Bunker Design Part 1: Bunker Outlet Design and Initial Measurements of Wall Pressures

by unknown authors
"... Experiments have shown that the Jenike bunker outlet design method is accurate with respect to both the flow pattern (mass flow or funnel flow) and the minimum outlet required. Initial measurements of wall pressures in a 0.6-m-dia mass flow bunker were used to select a suitable measuring technique ..."
Abstract - Add to MetaCart
Experiments have shown that the Jenike bunker outlet design method is accurate with respect to both the flow pattern (mass flow or funnel flow) and the minimum outlet required. Initial measurements of wall pressures in a 0.6-m-dia mass flow bunker were used to select a suitable measuring technique

Changes in the Lake Ladik fish community (1972-2004) and ichthyofauna of its inlet and outlet streams (Samsun, Turkey)*

by Selma Uğurlu, Nazmi Polat, Şevket Kandemi̇r
"... Abstract: This research was conducted to record the fish species inhabiting Lake Ladik and its inlet and outlet streams between July 2003 and August 2004. Electrofishing equipment, fishing cast net, fisherman’s dip net, and fishing nets with different scales were used to catch fish samples. As a res ..."
Abstract - Add to MetaCart
Abstract: This research was conducted to record the fish species inhabiting Lake Ladik and its inlet and outlet streams between July 2003 and August 2004. Electrofishing equipment, fishing cast net, fisherman’s dip net, and fishing nets with different scales were used to catch fish samples. As a

New Super-Portable UV Curing Equipment

by George Wakalopulos , Christy A Dennis
"... Abstract Magnetic ballasts have limited the portability of mercury lamps for decades, while new electronic ballasts trade-off weight against cost and simplicity. We'll describe the lightest, most powerful, and economical UV equipment in the world today, for hand-held and floor curing applicati ..."
Abstract - Add to MetaCart
Abstract Magnetic ballasts have limited the portability of mercury lamps for decades, while new electronic ballasts trade-off weight against cost and simplicity. We'll describe the lightest, most powerful, and economical UV equipment in the world today, for hand-held and floor curing

COMMUNICATIONS EQUIPMENT ROOM FITTINGS SPEC WRITER NOTES:

by unknown authors
"... 1.Use this section only for NCA projects. 2. Edit between //---//. Delete if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the remaining paragraphs. A. This Section specifies the furnishing, installing, certification, testing, and guara ..."
Abstract - Add to MetaCart
, and guaranty of a complete and operating Voice and Digital Cable Distribution System (here-in-after referred to as “the System”), and associated equipment and hardware to be installed in the NCA Facility, here-in-after referred to as “the Facility”. The System shall include, but not be limited to: equipment

SHAPE OPTIMIZATION ON DOUBLE-CHAMBER MUFFLER WITH SIDE INLET/OUTLET UNDER SPACE CONSTRAINT

by Ying-Chun Chang , Long-Jyi Yeh , Min-Chie Chiu , Gaung-Jer Lai
"... ABSTRACT The accessory facility of noise abatement is often confined for the necessity of equipment's maintenance and operation; therefore, how to ultimate the acoustic performance of mufflers within a limited space becomes an essential issue. This paper proposes an optimal design of a muffler ..."
Abstract - Add to MetaCart
ABSTRACT The accessory facility of noise abatement is often confined for the necessity of equipment's maintenance and operation; therefore, how to ultimate the acoustic performance of mufflers within a limited space becomes an essential issue. This paper proposes an optimal design of a

Safety Evaluation of Disposable Diesel Exhaust Filters for Permissible Mining Equipment

by Jeffrey L. Ambs, Robert S. Setren
"... Abstract manufacturer to ensure its use in this exhaust system The disposable diesel exhaust filter (DDEF) system cooperators for heavy-duty permissible, diesel-powered haulage vehicles, effectively reduces in-mine diesel Disposable pleated element filters, originally designed particulate matter co ..."
Abstract - Add to MetaCart
concentrations up to 95%. However, for cleaning the intake combustion air of diesel engines, there are concerns about the hazards that exist when the have been installed at the outlet of the exhaust gas

Good practices in the use of ICT equipment for electricity savings at a university campus

by Andreas Kamilaris, Dang Truong, Hoang Ngan, Ros Pantazaras, Balaji Kalluri, Sekhar Kondepudi, Tham Kwok Wai - in Green Computing Conference (IGCC), 2014 International
"... Abstract—The commercial sector is responsible in a large degree for the overall energy consumption around the world and Information and Communication Technologies (ICT) constitute an important category of electricity loads which is becoming dominant in offices. Recognizing the importance of using IC ..."
Abstract - Cited by 1 (0 self) - Add to MetaCart
ICT equipment more rationally for saving energy in commercial buildings, we have performed an energy audit of ICT loads at the School of Design and Environment, National University of Singapore, using smart power outlets. After a six-month period through which we have measured and analyzed

SIMULATION OF RADIAL COMPRESSOR AEROACOUSTICS USING CFD IGV -Inlet Guide Vanes MRF -Multiple Rotating Frames OEM -Original Equipment Manufacturer RPM -revolutions per minute PR -Pressure Ratio (outlet total pressure / inlet total pressure) SST -Shear Stre

by Fred Mendonça , Cd-Adapco , Shepherds Bush , UK Road London , Onur Baris , Geoff Capon , Ford Otosan , Ford Uk , Powertrain Engineering
"... ABSTRACT This paper focuses on the application of CFD to the prediction of radial compressor aeroacoustics. It concentrates mainly on automotive turbocharger operations in the low mass-flow range where blade leading-edge and tip separation reduce the compressor performance and induce transient flow ..."
Abstract - Add to MetaCart
ABSTRACT This paper focuses on the application of CFD to the prediction of radial compressor aeroacoustics. It concentrates mainly on automotive turbocharger operations in the low mass-flow range where blade leading-edge and tip separation reduce the compressor performance and induce transient flow behaviour. Whereas the blade-passing is tonal and at high frequency, usually beyond the human hearing range, transience in the flow are turbulence-dominated, broad-band in nature, and in magnitude a significant source of aeroacoustics which appears well within the range of peak human hearing (1-5kHz). Other noise sources occur due to distortions in the flow upstream of the compressor face, and rotating stall. The simulation methodology enumerated here pays attention to all the above flow-induced aeroacoustics. Due consideration is given to turbulence modelling, to ensure that both the narrow-band and broad-band sources are directly resolved in the CFD. Appropriate discretisation practices are adopted, so as to capture both turbulent-convection and soundpropagation mechanisms. Pressure-wave non-reflective boundary conditions are applied to the computational boundaries to remove any artificial resonances in the domain. STAR-CCM+, the commercial CFD code used here, was previously benchmarked against experimental data for the same compressor under ideal installation conditions, then the compressor performance assessed under real installation conditions

Modelling and Analysis of Hydropeaking in Alpine Catchments equipped with Complex Hydropower Schemes

by M. Bieri, A. J. Schleiss
"... Abstract: High-head storage hydropower schemes in Alpine areas are required to produce peak energy and to regulate electricity grids. Nevertheless the unsteady turbine operations induce hydropeaking in the river downstream of the powerhouse. The developed hydrological-hydraulic model can simulate gl ..."
Abstract - Add to MetaCart
hydropeaking at the outlet of the upper Aare River catchment is tested. Finally operation rules induced by the dynamic electricity market are simulated.

Thermal-aware task scheduling for data centers through minimizing heat recirculation

by Qinghui Tang, Eep K. S. Gupta, Georgios Varsamopoulos - in IEEE Cluster , 2007
"... Abstract — The thermal environment of data centers plays a significant role in affecting the energy efficiency and the reliability of data center operation. A dominant problem associated with cooling data centers is the recirculation of hot air from the equipment outlets to their inlets, causing the ..."
Abstract - Cited by 28 (5 self) - Add to MetaCart
Abstract — The thermal environment of data centers plays a significant role in affecting the energy efficiency and the reliability of data center operation. A dominant problem associated with cooling data centers is the recirculation of hot air from the equipment outlets to their inlets, causing